Renovation of brick or concrete facades and walls with RD-Elastoflex: A high-performance, waterproofing, and breathable coating.
RD-Elastoflexis a technical paint designed for waterproofing and protecting concrete, walls, and facades.
This elastic and water vapor-permeable coating provides effective protection against erosion, carbonation, and water infiltration while enhancing the building's aesthetics and allowing it to breathe.
%201024x683.jpg)
1024x683.jpg)
1%201024%20x683.jpg)
Products presented
RD-Elastoflex Technical paint designed for the waterproofing and protection of concrete, walls, and facades....
From €17.78 / Kg View
Technical paint designed for the waterproofing and protection of concrete, walls, and facades....
RD-Cement Filler Mineral powdery and dry mix based on cement, granulates and additives, for the repair of almost...
From €4.88 / Kg View
Mineral powdery and dry mix based on cement, granulates and additives, for the repair of almost...
RD-Cement Mix Water based emulsion based on synthetic resins to be used together with RD-Cement Filler for...
From €16.75 / L View
Water based emulsion based on synthetic resins to be used together with RD-Cement Filler for...
How to renovate a facade with RD-Elastoflex in video
The problem
Bricks, joints, and concrete walls undergo progressive deterioration due to weathering and structural movements of the building. These conditions promote the formation of cracks and increase the porosity of the materials, creating pathways for water and moisture to penetrate deeply, sometimes reaching the interior of the structures. During freeze-thaw cycles, the infiltrated water freezes, causing the cracks to expand and larger pieces of material to detach, thus worsening the damage.
On a deteriorated wall, applying regular paint is usually not sufficient to prevent moisture penetration, as it does not form an effective barrier against infiltration.
For a high-quality and durable renovation, it is recommended to apply a thicker coating with significant elasticity, capable of filling cracks while effectively blocking water infiltration. This type of coating should also allow the materials to breathe, promoting the escape of water vapor and preventing the risk of internal condensation, which could cause further deterioration.
The solution
RD-Elastoflex
This waterproofing coating is highly elastic and breathable, certified according to the European standard EN 1504-2. It provides protection against erosion, carbonation, and water infiltration.
It is a solution that regulates humidity by preventing internal condensation and allows for better crack bridging thanks to its high elasticity.
Its high-quality resin and pigments offer excellent resistance to soiling, keeping the protected objects looking impeccable for many years.
RD-Elastoflex is available in a wide range of colours!
For larger cracks or in the presence of severely damaged walls, the waterproofing system can be reinforced with RD-Mur Fleece fabric.
Depending on the case, RD-Mur Fleece is applied either over the entire facade or wall, or sporadically at a few more sensitive spots.
Thanks to this solution, rain will no longer pass through the walls, but internal condensation will still be able to escape!
System(s)
1/Non-porous or very slightly porous surface
Product | Consumption | Dry film | |||
1st layer | RD-Elastoflex | 0,40 kg/m² 155 s/f-g | 155 µ 6 mils | ||
2nd layer | RD-Elastoflex | 0,40 kg/m² 155 s/f-g | 155 µ 6 mils |
NB: Dilute the first coat with 10% water if the surface is slightly porous.
2/ Porous surface
Product | Consumption | Droge film | |||
Impregnation | RD-Unifix | > 0,10 L/m² | |||
1st layer | RD-Elastoflex | 0,40 kg/m² 155 s/f-g | 155 µ 6 mils | ||
2nd layer | RD-Elastoflex | 0,40 kg/m² 155 s/f-g | 155 µ 6 mils |
Application conditions and work preparation
Environmental conditions (general requirements):
• Minimum air and substrate temperatures: 10°C / 50°F for 24 hours.
• Maximum surface temperature: 55°C / 130°F.
• Maximum relative humidity: 80%.
• Surface temperature must be at least 3°C / 5°F above dew point.
• No threat of rain for 3 hours.
/!\ Notes
• There must be no condensation on the surface during application and drying. Caution when working at the beginning or end of the season!
• Overnight drying between coats is generally recommended. However, drying rates for water-based coatings depend on temperature, humidity and wind.
• From 15°C / 59°F, working conditions are comfortable and enable higher productivity.
• If the project is located in a very hot area with very intense sunshine during the day, avoid applying the system when the sun is most intense on the surface, and prefer to work early in the morning, late in the afternoon or in the shade.
Direct environment
Check for the possible presence of chimneys or ventilation outlets that may expel contaminants onto the surface to be treated. Neutralize their effects during the work.
Surface preparation
The surface must always be clean, dry, degreased, and free from any contaminants. Old paint layers with poor adhesion must be removed.
1. Biocide / anti-moss treatment
This should be considered in case of the presence of moss, lichens, and other biological growths. Remove thoroughly down to the roots with a certified biocide product available on the market.
It is also possible to use diluted bleach. This provides a curative but not preventive action. Be careful with stains!
2. Removal of efflorescence
Efflorescence is a white deposit that appears on the surface of construction materials, such as concrete or brick. Efflorescence is mainly an aesthetic issue, but it can also indicate excessive moisture presence, which could damage the material in the long term.
2.1. Dry brushing: Use a stiff-bristle brush to dry brush off the salt deposits. This removes most of the efflorescence without using water, which is important because water can dissolve the salts and cause them to re-enter the material.
2.2. Water cleaning: If dry brushing is not sufficient, you can use water and a brush to clean the surface. However, avoid using too much water.
2.3. Use of an acid cleaner: If the efflorescence is stubborn, a mild acid cleaner, such as diluted muriatic acid or a specific product for efflorescence, can be used. Apply carefully, following the manufacturer's instructions, and rinse thoroughly with water. Be cautious, as acid can damage certain materials and should be handled with care.
3. New masonry
New masonry should be brushed beforehand with a wire brush to remove any remaining mortar. The laitance must be removed.
4. Existing paint and blisters
Check the adhesion of the existing paint. Remove any paint that no longer adheres properly using a scraper.
Pierce and cut the blisters and remove any loose paint.
Never paint over a poorly adhering coating!
5. High-pressure cleaning at a maximum of 120 bar / 1700 psi
6. Repair cracks and repoint where necessary.
Cracks > 3 mm can be filled with RD-Cement Filler.
Cracks > 0.3 mm and < 3 mm can be filled with RD-Acryl W acrylic sealant or MS Polymer.
/!\ Porous and chalky surface
If the surface is porous, it is best to thoroughly impregnate it to saturation with RD-Unifix using a brush or low-pressure sprayer. Stop when the surface has a slightly satin appearance.
This also allows for better coverage of the following layers and prevents the RD-Elastoflex system from being absorbed into the concrete.
For moderately porous surfaces, another option is to dilute the first coat of RD-Elastoflex with about 10% water. This saves a step!
If the surface is chalky, apply a thin coat of RD-Unifix beforehand.
/!\ Smooth (new) surface
Apply a first bonding coat of RD-Elastodeck diluted with 25% water or a coat of RD-Multiprim.
/!\ Application of the reinforcement fabric RD-Mur Fleece
The fleece is applied to the surface after preparation and repairs.
RD-Mur Fleece is available in rolls of various widths, allowing easy adaptation to the substrate. It can be easily cut with scissors.
Use of fleece over the entire surface
Start from the highest point and apply a thick line of RD-Elastoflex as wide as the roll of RD-Mur Fleece.
Immediately after, place the roll on the line to secure it, without releasing the roll. Then gradually unroll the fleece along the surface while simultaneously applying RD-Elastoflex onto the fleece to secure it to the wall. As the fleece is perforated, the paint will pass through and bond it to the surface.
/!\ Avoid unrolling the fleece all at once, as the wind may lift it, making the installation more difficult.
Repeat the process as many times as necessary, and ensure an overlap of at least 3 cm / 1 inch between adjacent pieces of fleece.
/!\ It is advisable to have two people to perform this task.
Localized use of the fleece
RD-Mur Fleece is available in widths of 20 cm and can easily be cut to size for more localized reinforcement.
Apply a thick line of RD-Elastoflex the same width as the roll. Immediately after, place the RD-Mur Fleece roll in this line to secure it, without releasing the roll. Gradually unroll the fleece along the crack while simultaneously applying RD-Elastoflex to the fleece to secure it to the wall. As the fleece is perforated, the paint will pass through and bond it to the surface.
/!\ Avoid unrolling the fleece all at once, as the wind may lift it, making the installation more difficult.
Repeat the process as many times as necessary, and ensure an overlap of at least 3 cm / 1 inch between adjacent pieces of fleece.
Product application
RD-Elastoflex
Brush, roller, or airless (nozzle opening: 015 – 023).
Airless application is recommended as it makes it easier to achieve the recommended thicknesses.
Use a device that allows for a minimum pressure of 180 bar / 2600 psi at the outlet.
RD-Unifix
Brush, roller, or low-pressure sprayer.
Tool cleaning
Clean with clean water only.
Product application
RD-Elastoflex
Ready-to-use product.
Stir mechanically a few minutes before application.
Dilute to max. 3% with water for airless use in warm weather (> 25°C / > 77°F).
Drying time: (20°C - 68°F)
Touch-dry: +/- 2 hours
Recoatable: +/- 4 hours
RD-Unifix
Apply until saturation.
Drying time: (20°C - 68°F)
Touch-dry: +/- 1 hours
Recoatable: +/- 4 hours
VERS. S14-250402