    RD-Roof White

    Technical sheet

    White heat-reflecting roof coating, can also be used as reflective layer under solar panels.

    Single-component water-based paint that can be applied to various types of flat or sloping roofs. Helps to cool industrial, commercial and private buildings.

    RD-Roof White maintains its elasticity even in very cold weather, has good resistance to dirt accumulation and is formulated with high quality white pigments. These properties make it particularly suitable as a finish for roofs that need to be reflective.

    UV-reflective roofs drastically reduce the surface temperature of the roof and limit heat transfer inside the building. This technique can reduce the temperature inside the building by several degrees and reduce the consumption of air conditioning systems. This technique has been known for many years and is often referred to as Cool Roof.

    RD-Roof White is water-based, easy to handle, safe and has no fire risks. It is a fast-drying coating system that greatly reduces downtime during installation and increases on-site labour productivity. Virtually odour free, it does not affect neighbouring occupants and can therefore be used in occupied buildings.

    Available colors

    Click here to chose your color
    RAL 1000 Lorem Ipsum

    Packaging

    25 kg
    Surface 1 coat: 50.00m²
    Total quantity selected (Kg): 0
    Theoretical surface that can be painted in 2 coats with the ordered quantity (*) : 0

    (*) the quantity indicated is theoretical and is based on a standard consumption of the product as described in the technical sheet below. This consumption is also influenced by the nature of the support and the method of application.

    Technical sheet

    Description of the product

    USE: 

    White heat-reflecting roof coating, can also be used as reflective layer under solar panels.

    FEATURES:

    Single-component water-based paint that can be applied to various types of flat or sloping roofs.

    RD-Roof White maintains its elasticity even in very cold weather, has good resistance to dirt accumulation and is formulated with high quality white pigments. These properties make it particularly suitable as a finish for roofs that need to be reflective. UV-reflective roofs drastically reduce the surface temperature of the roof and limit heat transfer inside the building. 

    This technique can reduce the temperature inside the building by several degrees and reduce the consumption of air conditioning systems.

    RD-Roof White is water-based, easy to handle, safe and has no fire risks. It is a fast-drying coating system that greatly reduces downtime during installation and increases on-site labour productivity. Virtually odour free, it does not affect neighbouring occupants and can therefore be used in occupied buildings.

    SUBSTRATES:

    Bituminous roofing, concrete, after application of a primer such as RD-Elastodeck. On synthetic roofs, such as Trocal, an adhesion test must be done beforehand.

    Systems

    On existing paint:

    Wet film thickness in microns / mils

    Dry film thickness in microns / mils

    Consumption per m² / ft² per gallon

    Comments

    RD-Roof White

    360 / 14,5

    180 / 7,2

    0,5 kg / 110

    TOTAL

     

    180 / 7,2

     

    On a bituminous roofing > 1 year old with a slope < 4% and no defects (such as leaks, cracks,...):

    Wet film thickness in microns / mils

    Dry film thickness in microns / mils

    Consumption per m² / ft² per gallon

    Comments

    Primer

    RD-Elastodeck

    800 / 32

    440 / 17,6

    1 kg / 50

    Finish

    RD-Roof White

    360 / 14,5

    175 / 7,2

    0,5 kg / 110

    TOTAL

     

    620 / 25

     

    If the roof is leaking, please refer to our solution "How to restore a flat roof covered with a bituminous roofing?" in our Solutions pages describing the procedure to follow.

    Indicated consumption is theoretical and does not consider potential losses during application. It can also be influenced by the porosity of the substrate.

    Application instructions

    APPLICATION CONDITIONS:

    Ambient temperature: minimum 5°C (41°F) – optimal between 12 and 25°C (54 and 77°F).
    Relative humidity: maximum 80 %
    Surface temperature must be minimum 3°C (5°F) above dew point.

    APPLICATION MEANS:

    Brush, roller or airless 
    Airless: nozzle size 015 to 023 - prressure +/- 180 bars (+/- 2600 psi).

    PREPARATION OF THE SUBSTRATE:

    The preparation depends on the substrate. The substrate must be clean and degreased before applying the painting system.

    1. Clean the surface thoroughly with a high pressure cleaner. The formation of foam or algae can be removed with a suitable defoamer.

    2. The surface must be completely clean and dry. In case of sealing problems, please refer to our solutions pages.

    WARNING: For all types of substrates, the interior spaces must be provided with sufficient vapour barriers and roof ventilations to prevent condensation from forming under the roof covering.

    Sufficient slope to the downpipes must be provided to collect rainwater and avoid standing water.

    DILUTION:

    Product is ready-for-use.

    DRYING TIME (20°C - 68°F):

    Touch dry: +/- 3 hours
    Recoatable: +/- 6 hours

    CLEANING OF TOOLS:

    Water

    SPECIFICITIES:

    Mix well before use.

    The temperature of flat, sloping or corrugated roofs can be extreme. Under the influence of the sun, the surface temperature during the summer months can reach over 80°C. In case of sudden cooling, precipitation or storms, thermal shocks can damage the roof and the building. On a white covering, this temperature can drop to 35°C. RD-Roof White is a thermal insulator that reflects direct light by more than 80%.

    Technical data

    FINISH:

    Satin

    COLOURS:

    White

    DENSITY:

    1.43 +/- 0.05 g/cm³

    SOLIDS CONTENT:

    In weight:  ca. 65 %
    In volume: ca. 50 %

    VISCOSITY:

    150 - 200 P (Brookfield 20 RPM)

    VOC CONTENT:

    Max. 30 g/l

    FLASH POINT:

    Not flammable

    STORAGE:

    Minimum 24 months protected from frost and excessive temperatures in its original closed packaging. 

    Norms & tests

    Title

    Norms

    Results

    Red List Compliance

    Living Building Challenge v3

    passed

    VOC-emissions

    ISO 16000-6 / VOS classification in France

    SRI - Solar Reflectance Index

    ASTM E1980-11

    +/- 105

    Solar reflectanceASTM E903-12+/- 89%
    Thermal reflectanceASTM C1371+/- 83%

    Safety data

    Information related to hygiene and to safety can be found in the Safety Data Sheet available on request.

    These specifications are given for information. Since the manufacturer is not able to check the application of the products, he cannot accept any responsibility for it. This technical data sheet replaces all previous editions.